Pengembangan Pembalut Pintar untuk Deteksi Dini Kondisi Hiperurisemia dan Hiperkolesterolemia

  • Itut Septiana Dewi Fakultas Farmasi Universitas Jember
  • Bambang Kuswandi Fakultas Farmasi Universitas Jember
  • Ari Satia Nugraha Fakultas Farmasi Universitas Jember

Abstract

Hyperuricemia and hypercholesterolemia’s cases are increasing. Noninvasive early detection method should be develope. Development of smart sanitary napkins based on paper chip biosensors using “Whatman” filter paper through screen printing and immobilized with pH 6 citrate buffer and iron (III)-actress- (1,10-phenanthroline) complex reagent for detection of uric acid and cholesterol oxidase enzymes and reagent 2,2'-azino-bis (3-ethylbenzthiazoline-6-sulfonic acid (ABTS)) for cholesterol detection. The analysis of the paper chip biosensor has a response time of 10 minutes for uric acid detection and 25 minutes for cholesterol detection. Uric acid linearity 2 - 20 mg / dL and cholesterol 50 - 500 mg / dL. The LOD and LOQ detection areas for uric acid were 0.322 mg / dL and 0.965 mg / dL, respectively, while the cholesterol detection areas were 8.740 mg / dL and 26.221 mg / dL, respectively. NaCl interference interfering with the detection of uric acid and cholesterol was 5.746% and 6.388%, respectively and creatinine interference interfering with the detection of uric acid and cholesterol was 5.868% and 5.583%, respectively. The precision for uric acid detection was 1.252% (RSD <3.7%) and cholesterol detection was 0.059% (RSD <2.7%). The accuracy (% recovery) for uric acid detection was 100.333% and for cholesterol, the detection was 100.016%. Smart bandages can be used to analyze the initial conditions of hyperuricemia and hypercholesterolemia.

References

[1] Maryani H, Handajani A, Roosihermiatie B. Faktor-faktor yang berhubungan dengan pola kematian pada penyakit degeneratif di indonesia. Buletin Penelitian Sistem Kesehatan. 2010. 13(1):42–53.
[2] Dalimartha S. Atlas Tumbuhan Obat Indoneia. Edisi Jilid 2. Jakarta: PT. Pustaka Pembangunan Swadaya Nusantara. 2000.
[3] Khasanah M, Supriyanto G, Handajani S. Deteksi Sensitif Asam Urat Secara Stripping Voltammetry Menggunakan Hanging Mercury Drop Electrode (HMDE). Universitas Airlangga. 2006.
[4] Simamora RH, Saragih E. Penyuluhan kesehatan masyarakat : penatalaksanaan perawatan penderita asam urat menggunakan media audiovisual. Jurnal Pendidikan Dan Pemberdayaan Masyarakat. 2019. 6(1):24–31.
[5] Listiyana A, Mardiana D, Prameswari GN. 2013. Obesitas sentral dan kadar kolesterol darah total. KESMAS - Jurnal Kesehatan Masyarakat. 2013. 9(1):37–43.
[6] Zhao C, Wan L, Jiang L, Wang Q, Jiao K. Highly sensitive and selective cholesterol biobiosensor based on direct electron transfer of hemoglobin. Analytical Biochemistry. 2008. 383:25–30.
[7] Faridha DI. Prevalensi Hiperkolesterolemia Pada Pasien Usia Remaja Di Laboratorium Klinik Thamrin Medan Tahun 2017. Universitas Medan Area. 2019
[8] Siswanto. Darah Dan Cairan Tubuh. Universitas Udayana. 2017.
[9] Samukange WT, Gardarsdottir H, Leufkens HGM, Mantel-Teeuwise AK. Selection of blood, blood components, and blood products as essential medicines in 105 low- and middle-income countries. Transfusion Medicine Reviews. 2019:1–7.
[10] Yang H, Zhou B, Prinz M, Siegel D. Proteomic analysis of menstrual blood. Molecular and Cellular Proteomics. 2012.11(10):1024–1035.
[11] Gibson L, Yamakoshi B, Burgers L, Alleman P. Menstrual Health and Hygiene. Dalam Unicef for Every Child. Editor P. Poirier. New York: UNICEF. 2019.
[12] Yu Z, Kastenmüller G, He Y, Belcredi P, Möller G, Prehn C, et al., Differences between human plasma and serum metabolite profiles. PLoS ONE. 2011. 6(7):1–6.
[13] Prihatiningrum IR. Pengembangan Biosensor Kimia Optik Untuk Deteksi Asam Urat Berbasis Membran Ferriin. Universitas Jember. 2007.
[14] Hayat A, Haider W, Raza Y, Marty JL. Colorimetric cholesterol biosensor based on peroxidase like activity of zinc oxide nanoparticles incorporated carbon nanotubes. Talanta. 2015. 143:1–19.
[15] Pramulia R. Pengembangan Pembalut Pintar Untuk Deteksi Dini Anemia Defisiensi Besi. Universitas Jember. 2011.
[16] Gandjar IG. Rohman A. Kimia Farmasi Analisis. Yogyakarta: Pustaka Pelajar. 2007.
[17] Huber L. Validation and Qualification in Analytical Laboratories, 2nd Ed. New York: Taylor & Francis. 2007.
Published
2024-07-31
How to Cite
DEWI, Itut Septiana; KUSWANDI, Bambang; NUGRAHA, Ari Satia. Pengembangan Pembalut Pintar untuk Deteksi Dini Kondisi Hiperurisemia dan Hiperkolesterolemia. Pustaka Kesehatan, [S.l.], v. 12, n. 2, p. 85-92, july 2024. ISSN 2721-3218. Available at: <https://jurnal.unej.ac.id/index.php/JPK/article/view/22412>. Date accessed: 15 oct. 2024. doi: https://doi.org/10.19184/pk.v12i2.22412.