ANALISIS KETAHANAN FATIGUE PADA HEX SOCKET HEAD BOLT A325 DENGAN ULIR DAN TANPA ULIR

FATIGUE RESISTANCE ANALYSIS ON HEX SOCKET HEAD BOLT A325 WITH THREAD AND WITHOUT THREAD

  • Muhammad Hilmi Aziz Jember

Abstract

This research was conducted at the LAB of the Faculty of Engineering, University of Jember from September 2020 to July 2021. This study used Ansys Student 19.1 Software and analytical calculations of fatigue life. Data retrieval is carried out on bolts hex socket  head bolt with and without thread This research was conducted under static conditions. bolt hex  socket head bolt has a size with a length of p = 70 mm, thread diameter = 12 mm. Material  bolts using ASTM A325 steel. The results of this study include, stress, fatigue life, fatigue damage and safety factor. From the results of the study, it can be concluded that the results of the comparison between simulation and analysis in table 4.4 have a significantly greater comparison between fatigue life and fatigue damage namely 62.73% and 99.76%, respectively. While in table 4.5 the comparison is significantly greater in the fatigue damage and safety factor , namely 89.97% and 54.59%, respectively. In the comparison results, it still exceeds the errorassumptions cycle bolt hex socket head

Published
2022-06-07
How to Cite
AZIZ, Muhammad Hilmi. ANALISIS KETAHANAN FATIGUE PADA HEX SOCKET HEAD BOLT A325 DENGAN ULIR DAN TANPA ULIR. STATOR: Jurnal Ilmiah Teknik Mesin, [S.l.], v. 2, n. 1, p. 1-3, june 2022. ISSN 2962-228X. Available at: <https://jurnal.unej.ac.id/index.php/STATOR/article/view/29989>. Date accessed: 24 nov. 2024.